Boiler Water Sample Cooler Using

Sample Cooler SCC2 with Valve Assembly2019-1-17 · 5. Better safety for personnel doing water analysis 6. Better test results achieved using a sample cooler

Details


  • Production capacity: 0.5-20 t/h
  • Work pressure: 0.7-2.5 Mpa
  • Applicable fuel: Nature gas, coke oven gas, biogas, methanol, etc.
  • Applicable industry: heat suppling, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.


Product introduction

  WNS series horizontal internal combustion boiler is a boiler shell type 3 passes wetback oil/gas fired boiler. After fuel is being atomized by burner, flame is full of the wave furnace and transfer heat via furnace wall, this is 1st pass; the high temperature smoke is collected in reversal chamber and then enters 2nd pass which is grooved tubes bundle area; after heat convection, air temperature gradually falls and goes to front smoke box and turn to 3rd pass, which is smooth tubes bundle area, and then enters chimney passing back smoke box and exhausted to the atmosphere.


Quick inquiry:
I need the quotation of , the fuel is , this capacity is , the pressure is , use for . My Name is , my Email is , my phone number is , Please Send the detail information for me!






Digitized manufacture
The key part such as material cutting, rolling, drilling are proceeded by advanced CNC machining process to reduce the assemble stress and extend boiler working lifetime.
● The front and back smoke chamber plates are cut by CNC plasma cutting machine and looks tidy and beautiful;
Easy operation and maintenance
Fully automatically operating, with automatically adjustment and protection of burning, water level, temperature and steam pressure
longer working life.
Smoke tube and tube sheet connection is expanded first to eliminate the gap between them, then adopt automatic argon arc welding to relief the stress and expand boilers working life.
Longitudinal and girth joint adopt advanced automatic submerged-arc welding for good welding quality. All longitudinal and girth joint will have 100% radiographic inspection.
Fin tube us ND steel or stainless-steel material which avoid low temperature corrosion.
  Inspection procedure point is set up to guarantee the sequence of expanding and welding, avoid cracking of the tube sheet holes
less fuel consumption
High quality aluminum silicate fiber is used with fire clay insulation, to control the boiler body temperature below 45℃ to control heat lost.
Sufficient steam storage room and heating area makes boiler to generate high quality steam and high thermal power
Condenser is added to reuse the waste heat of the exhausted smoke to increase feeding water’s temperature and reduce emission temperature, which can increase the thermal efficiency above 98% and save operating cost.
Model Ratedsteamcapacity(t/h) Ratedworkingpressure(Mpa) Ratedsteamtemperature(℃)
WNS1-0.7-Y(Q) 1 0.7 170
WNS1-1.0-Y(Q) 1 1 184
WNS1.5-1.0-Y(Q) 1.5 1 184
WNS1.5-1.25-Y(Q) 1.5 1.25 194
WNS2-1.0-Y(Q) 2 1 184
WNS2-1.25-Y(Q) 2 1.25 194
WNS3-1.0-Y(Q) 3 1 184
WNS3-1.25-Y(Q) 3 1.25 194
WNS4-1.25-Y(Q) 4 1.25 194
WNS4-1.6-Y(Q) 4 1.6 204
WNS5-1.25-Y(Q) 5 1.25 194
WNS5-1.6-Y(Q) 5 1.6 204
WNS6-1.25-Y(Q) 6 1.25 194
WNS6-1.6-Y(Q) 6 1.6 204
WNS8-1.25-Y(Q) 8 1.25 194
WNS8-1.6-Y(Q) 8 1.6 204
WNS10-1.25-Y(Q) 10 1.25 194
WNS10-1.6-Y(Q) 10 1.6 204
WNS15-1.25-Y(Q) 15 1.25 194
WNS15-1.6-Y(Q) 15 1.6 204
WNS20-1.25-Y(Q) 20 1.25 194
WNS20-1.6-Y(Q) 20 1.6 204

CONTACT FORM



  • Sample Cooler SCC2 with Valve Assembly

    2019-1-17 · 5. Better safety for personnel doing water analysis 6. Better test results achieved using a sample cooler as the cooling equipment rather than allowing the sample to cool on its own and thus, causing steam flashing 7. The sample cooler reduces the temperature of boiler water to around 25° C for immediate analysis 8.

    Get a Quote
  • "Save $91,000 Annually In Low Pressure Boiler Water

    2015-4-16 · They currently have a boiler feed water system incorporating a makeup water softener and deaerator. One of the largest uses of steam is in a large steam dryer that demands high steam rates and produces high flows of condensate with high CO 2 levels. When measured using a sample cooler, the pH values are reported to be around 5.8. While

    Get a Quote
  • Sample Cooler - EWT Water Technology

    2018-5-13 · A sample cooler serves for safe sampling, cooling and if applicable condensation of hot fluids. The following descriptions are limited to water to water heat exchangers used in steam boiler plants and hot water boiler plants for the above purposes. A sample cooler consists of a

    Get a Quote
  • Sterilizing Using Steam Boiler - die-gartengestalter.de

    Applications for Steam in the Food and Beverage Industry. 2011-1-3 · boiler horsepower.It is rated to produce 34.5 lbs.per hr.of steam which equates to 33,500 BTUs per hour.The water consumption necessary to produce this amount of steam is only 3.1 gal.per hr.(Note: boilers and steam generators are rated on the basis of using 212º F feed water.

    Get a Quote
  • Installation, Operation & Maintenance Manual Sentry

    2017-11-9 · Installation, Operation & Maintenance Manual Sentry Single Helical Tube Sample Coolers S-SW-IOM-00268-6 8-16 Do not install, maintain, or operate this equipment without reading, sample cooler is used to cool a sample from a process stream. Because the process (included with the cooler) using included nuts or by water lines only. Care

    Get a Quote
  • Heat Transfer Products Heliflow Heat Exchanger

    The Graham Clean Steam Generator is designed to produce clean, chemical-free steam from clean feed water, using plant steam as the energy source. Blowdown. Boiler blowdown and process sample coolers are perfect applications for a Heliflow heat exchanger. The compact size of

    Get a Quote
  • Sentry Sample Coolers

    2017-10-11 · used in low pressure boiler application where a small volume of sample is required. SENTRY WSW SERIES The WSW sample cooler is designed for high viscosity/low pressure drop service and is useful in cooling slurries and very low pressure samples. Sample Inlet 1/4" O.D. Tube Sample Outlet 1/4" O.D. Tube 3/8" FNPT Cooling Water Outlet 3/8

    Get a Quote
  • Boiler Water & Feed Water Analysis | Chemistry

    Safety precautions should be adhered too if sampling from a sample cooler, if in doubt seek advice. If your site looks after the treatment of your boiler and you need regular boiler water analysis to ensure effective treatment our boiler water testing sample pack will help achieve this.

    Get a Quote
  • Introduction to Sample Cooler - The Process Piping

    Precautions while Operating Sample Cooler. To avoid the risk of scalding, it is essential that a full flow of cooling water is present before opening the sample inlet valve. Always close the sample inlet valve before turning off the cooling water. Sample pipework becomes very hot under normal working conditions and will cause burns if touched.

    Get a Quote
  • SC20 Sample Coolers and Systems - Spirax Sarco

    2015-9-10 · The Spirax Sarco SC20 sample cooler is used to cool samples of boiler water or steam. The cooler consists of a stainless steel coil, through which the sample flows, and a stainless steel body, through which cooling water flows in the opposite direction. The

    Get a Quote
  • Amazon.com: Sample Cooler

    Boiler Sample Cooler. $517.00 $ 517. 00. FREE Shipping. Only 2 left in stock - order soon. Neptune Sample Cooler SC-316. $459.50 $ 459. 50. FREE Shipping. Only 14 left in stock - order soon. for Drink Dispensers, Coolers and Insulated Water Jugs (Set of 2) 3.8 out of 5 stars 129. $12.75 $ 12. 75. Get it as soon as Thu, Sep 26. FREE

    Get a Quote
  • SAMPLE COOLERS - HEAT EXCHANGERS -

    SAMPLE COOLERS in many types for LIQUID & GAS SAMPLING APPLICATIONS, sample cooling down & conditioning of hot liquid and gas sample fluids. HERPI Steam coolers, Sentry coolers, Liquid sample cooling down, Gas sample cooling down for CEMS measurement, electrical compressor gas coolers, Helical coil water coolers heat exchangers tube and shell, Tube-in-Tube sample coolers, Open flanged water

    Get a Quote
  • Boiler Sample Cooler - Richard Hourigan, Inc

    2019-5-8 · The rugged (10% price discounted) LBC boiler sample cooler provides a safe method of withdrawing water samples from high temperature or pressure applications. This product is also sometimes referred to as a cooling coil or heat exchanger. This model is but one of a number of sample coolers that we can provide.

    Get a Quote
  • Boiler Water Sample Cooler, Stainless Steel, 2,500 psi

    Boiler Water Sample Coolers are a safe method to cool down water samples. This Rugged Counter Flow Heat Exchanger is easy to install. Boiler Sample Cooler, Stainless Steel, 2,500 psi. The Compact ClO 2 + meter provides field analysis of chlorine and chlorine dioxide using the DPD method.

    Get a Quote
  • Boiler Water Conductivity Measurement Fundamentals

    Boiler Water Conductivity Measurement Fundamentals. As a boiler generates steam, any impurities which are in the boiler feedwater and which do not boil off with the steam will concentrate in the boiler water. Inside the boiler the heat generates steam bubbles inside the water.

    Get a Quote
  • SAMPLE COOLERS - ecotekproducts.com

    2014-10-8 · disconnecting sample water lines. Lowest Cost: † Largest heat transfer surface per unit of cost of any sample coolers. PRODUCT OFFERING The sample cooler is a low-pressure-drop system for monitoring boiler water quality without shutting down the boiler system. A simple, compact design cools samples with minimum disturbance to system pressure.

    Get a Quote
  • Sample Cooler - cleaverbrooks.com

    2018-8-5 · Sample Cooler 2 750-286 1. General Description A sample cooler is a small shell and coil heat exchanger. The sample to be cooled (or heated) flows through the tube side of the cooler. The cooling fluid, usually water, flows through the shell side of the cooler. A sample cooler is used to cool a sample from a process stream. Because the process

    Get a Quote
  • STANDARD_AMERSITE_CHZ_CS__

    2012-2-28 · Fill the sample cup to the 25-ml mark with cooled boiler water sample (Fig. 1 & 2). 2. Place AMERZINE corrosion inhibitor ampoule's tapered tip into one of the four depressions in the bottom of the sample cup. Snap the tip by squeezing the ampoule toward the

    Get a Quote
  • Boiler Water/Feedwater Flashcards | Quizlet

    Alkalinity reading of less than 0.050 epm or greater than 1.500 epm, Phosphate of less than 5 ppm, conductivity more than 1500 umhos/cm and dissolved oxygen in the feedwater entering the boiler is greater than 15 ppb for more than how many hours after detection is defined as serious boiler water

    Get a Quote
  • Sampling coolers - Jumag Dampferzeuger ||

    Boiler water and condensate cannot be removed easily because they are pressurised. The sampling cooler is ideal for cooling and taking water samples. To perform these measurements better, lines are placed from the sampling locations to the sampling cooler in which the sample water is cooled with cold water using a heat exchanger.

    Get a Quote